BannerTM550FM

MAGNETIC INDUCTION AND EDDY CURRENT 

This compact gauge can be used for non-destructive coating thickness measurement of non-magnetic coatings, e.g. paint, enamel, chrome on steel, and insulating coatings, e.g. paint and anodizing coatings on non-ferrous metals. The internal probe can work on both principles, magnetic induction and the eddy currents. The probe can automatically detect the substrates type (Magnetic or not), and calculate the coating thickness and display it fast.

FIVE DATA GROUPS AND INDIVIDUAL STATISTICS

There are five data groups, and readings will be automatically stored to memory for general groups (Not for direct group). Each group has individual statistics, alarm limit settings and calibration. User can recall and delete specified readings easily. User does all operations via standard menu so easily. User can press the CAL button to start calibration freely.

 

 

TM_Lado1

MAGNETIC INDUCTION AND EDDY CURRENT 

This compact gauge can be used for non-destructive coating thickness measurement of non-magnetic coatings, e.g. paint, enamel, chrome on steel, and insulating coatings, e.g. paint and anodizing coatings on non-ferrous metals. The internal probe can work on both principles, magnetic induction and the eddy currents. The probe can automatically detect the substrates type (Magnetic or not), and calculate the coating thickness and display it fast.

FIVE DATA GROUPS AND INDIVIDUAL STATISTICS

There are five data groups, and readings will be automatically stored to memory for general groups (Not for direct group). Each group has individual statistics, alarm limit settings and calibration. User can recall and delete specified readings easily. User does all operations via standard menu so easily. User can press the CAL button to start calibration freely.

TM_Lado1

 

 

 

 

 

 

 

 

Características

Datos principales

  • 128*128 dot matrix LCD display, standard menu operations
  • Two measure mode: single and continuous
  • Two group mode: direct (DIR) and general(GEN), readings will be lost when power off in direct mode, and not be lost in general mode. 80 readings can be stored for each group
  • Zero point calibration and multi-point calibration(up to 4 points) for each group
  • User can recall, delete specified readings, or delete group readings
  • Statistics display: mean, minimum, maximum and standard deviation
  • Three probe mode: auto, magnetic and eddy current
  • User can set high or low limit alarm for each group
  • Power off automatically
  • USB interface to data transmission
  • Low battery and error indication;

 

Características 

Datos principales

  • 128*128 dot matrix LCD display, standard menu operations
  • Two measure mode: single and continuous
  • Two group mode: direct (DIR) and general(GEN), readings will be lost when power off in direct mode, and not be lost in general mode. 80 readings can be stored for each group
  • Zero point calibration and multi-point calibration(up to 4 points) for each group
  • User can recall, delete specified readings, or delete group readings

 

 

  • Statistics display: mean, minimum, maximum and standard deviation
  • Three probe mode: auto, magnetic and eddy current
  • User can set high or low limit alarm for each group
  • Power off automatically
  • USB interface to data transmission
  • Low battery and error indication;

MEASURING PRINCIPLE

Magnetic induction (F-probe) and eddy current (N-probe)

MEASURING RANGE

0 to 1300um (0 to 51.2mils); ± (3% of readings+0.078mils)

ACCURACY

± (3% of readings+2um)

RESOLUTION

0um~999um (1um), 1000um~1300um (0.01mm)

CALIBRATION

One to four point calibration, zero calibration

DATA GROUP

One direct group (readings not be stored to memory), four general group (readings can be stored), and each group have individual statistics, alarm settings and calibration

STATISTICS

No. of readings, mean, minimum, maximum and standard deviation; 8. Units: um, mm and mils

ALARM

User can set the high/low alarm, and alarm icon displayed on LCD when over the limit

MINIMUN CURVATURE RADIUS

Convex 1.5mm(59mils) and concave 25mm(984mils);

MINIMUM MEASURING SIZE

Diameter 6mm(236mils)

MINIMUM THICKNESS OF SUBSTRATE

F-probe: 0.5mm(0.02″), N-probe: 0.3mm(0.012″)

COMPUTER INTERFACE

Download data via USB interface

POWER SUPPLY

Two 1.5v AAA battery

OPERATION TEMPERATURE

0℃ to 40℃(32℉ to 104℉

STORAGE TEMPERATURE

-20℃ to 70℃(-4℉ to 158℉)

SIZE

110mm*53mm*24mm (4.33″*2.09″*0.94″)

WEIGHT

92g (3.24oz)