Banner_TM510FN

FEATURES THAT MATTERS

Can use various probe (F400, F1, F1/90 °, F10, N1, N400, etc.) measurement;
Three calibration methods: one point calibration,
two point calibration, the basic calibration;
Display resolution: 0.1 μ m (measuring range of less than 100 μ m)
1μ m (range greater than 100 μ m)
Have five statistics, data storage 500
There are two working methods: direct ways and means of group
There are two measurements: continuous measurement and a single measurement
There are two shutdown: manual and automatic shutdown shutdown

ADDITIONAL FEATURES

Can be set Bound: The gauge of the measured value can be automatic alarm and a number of measurements available on the histogram value analysis.
Deleted features: the gross error and error settings can be deleted.
Printing: Print Measurement measurement, statistics, gauges, histogram.
A music tone in the operation carried out at any time tips.
A power supply under-voltage direct function.
An error function.
And printers, computer communications (communications software operating environment for the Window operating system) connectivity.

 

 

 

 

 

 

 

Características

Datos principales

  • 2 Measuring modes: continuous/single
  • 2 Shutdown modes: manual/automatic
  • Wide measuring range with 5 probes available (next page)
  • Direct testing mode and block statistics mode (APPL/BATCH)
  • Can connect with printer to out of statistical values
  • Dataview to connect with PC with USB 2.0 port
  • 500 datas can be stored

 

Características 

Datos principales

  • 2 Measuring modes: continuous/single
  • 2 Shutdown modes: manual/automatic
  • Wide measuring range with 5 probes available (next page)
  • Direct testing mode and block statistics mode (APPL/BATCH)

 

 

  • Can connect with printer to out of statistical values
  • Dataview to connect with PC with USB 2.0 port
  • 500 datas can be stored

MEASURING RANGE

0-1250µ with standard probe F1.N1 (10.000mm max)

PROBES AVAILABLE  

5 probes available for F (ferrous: on steel/iron) and N (non-ferrous metals)

TOLERANCE  

F1:±(1µ+3%H) N1.±(1.5µ+3% H)

H: actual thickness tested

RESOLUTION

Alphanumeric with 4 large digits

OPERATION LANGUAGE

English

STANDARDS

DIN, ISO, ASTM,BS

MIN. MEASURING AREA 

F1:(standard probe)

MIN. CURVATURE  RADIUS

convex:3mm, concave:50mm

MIN. SUBSTRATE THICKNESS 

type F: 0.5mm, type N: 50mm

CALIBRATION 

Zero and foil calibration

STATISTICS

Number of measurements, mean, standard deviation,

maximum and minimum of 3000readings

DATA MEMORY 

500  measuring data

LIMITS 

Adjustable with acoustic alarm

INTERFACE 

USB 2.0

OPERATING TEMPERATURE

0-40℃

POWER SUPPLY 

AA size 1.5V

DIMENSIONS 

125*67*31mm (main unit)

WEIGHT 

345.g