TG930-Banner

Single Element:
Can only use single element probes

Alarm Mode:
Alarm mode on limits

Differential Mode:
Differential measurement from set value

Auto Zero:
Can automatically zero thickness

Adjustable Gain:
Gain can be adjusted

Data Logging:
Data logging in gauge

Scrolling B-Scan
Displays Time based
B-scan

Variable Units:
Change between mm/ inch

Multi-Probe:
Can use multiple probe
types

High Resolution:
Resolution to 0.0001

Handheld:
Designed for handheld use

Rechargeable:
Can be recharged

Auto Probe Recognition:
Automatically recognizes
probe type

Adjustable Velocity:
Velocity can be adjusted

Point Calibration:
Single & Two point calibration

Min/ Max Mode:
Measures max and min thickness

 

APLICACIONES DIVERSAS

 

FRESADO QUÍMICO
FUNDICIONES DE INVERSIÓN
ÁLABES DE TURBINAS
DUCTOS Y TUBERÍA
TANQUES
RECUBRIMIENTO DE CALDERAS
METALES, PLÁSTICOS
COMPUESTOS, VIDRIO, CAUCHO

 

Single Element:
Can only use single element probes

Alarm Mode:
Alarm mode on limits

Differential Mode:
Differential measurement from set value

Auto Zero:
Can automatically zero thickness

Adjustable Gain:
Gain can be adjusted

Data Logging:
Data logging in gauge

Scrolling B-Scan
Displays Time based B-scan

Variable Units:
Change between mm/ inch

Multi-Probe:
Can use multiple probe types

High Resolution:
Resolution to 0.0001

Handheld:
Designed for handheld use

Rechargeable:
Can be recharged

Auto Probe Recognition:
Automatically recognizes probe type

Adjustable Velocity:
Velocity can be adjusted

Point Calibration:
Single & Two point calibration

Min/ Max Mode:
Measures max and min thickness

FRESADO QUÍMICO
FUNDICIONES DE INVERSIÓN
ÁLABES DE TURBINAS
DUCTOS Y TUBERÍA
TANQUES
RECUBRIMIENTO DE CALDERAS
METALES, PLÁSTICOS
COMPUESTOS, VIDRIO, CAUCHO

 

 

 

 

 

 

 

 

 

 

Características

Datos principales

  • Standard package includes instrument,
    Pelican style shipping case, manual, batteries and AC charger
  • Backlight- on/off/auto
  • Single and two point calibration
  • Coupling indicator
  • Minimum thickness capture mode
  • Data logging
  • Programmable user setups
  • Time encoded B-scan, 500Hz response
  • Thickness scan bar
  • Viewport output connector to Oscilloscope (option)

 

TG930Producto

Características 

Datos principales

  • Standard package includes instrument,
    Pelican style shipping case, manual, batteries and AC charger
  • Backlight- on/off/auto
  • Single and two point calibration
  • Coupling indicator
  • Minimum thickness capture mode
  • Data logging
  • Programmable user setups
  • Time encoded B-scan, 500Hz response
  • Thickness scan bar
  • Viewport output connector to Oscilloscope (option)

 

PESO

0.8lb (0.36kg)

DIMENSIONES

3.00pulg. x 4.90pulg. x 1.25pulg (76mm x 99mm x 32mm)

TEMPERATURA DE OPERACIÓN

14 °F a 122 °D (-10 °C a 50 °C)

CONSTRUCCIÓN DE CARCASA

Cuerpo de aluminio, tapas de caucho

TIPO DE CONECTOR

Lemo00

CONSTRUCCIÓN DE KEYPAD

Teclas realimentación de membrana táctil

TIPO DE TRANSDUCTOR

Transductor de un solo elemento (contacto/retardo)

RANGO DE FRECUENCIA

0.5MHz a 35MHz

LARGO DE CABLE

6pies (1.83m) estándar

FUENTE DE ALIMENTACIÓN

2x baterías recargables AA NiMH

DURACIÓN DE BATERÍA

150 horas

TIPO DE PANTALLA

Cristal líquido retroiluminado

TAMAÑO DE PANTALLA

128 X 64 pixeles, 1.96pulg. x 1.25pulg. (50mm x 32mm)

CERTIFICACIÓN

Calibración de fábrica

RANGO DE MEDICIÓN DE ESPESOR

0.005 pulg. a 20.000 pulg. (0.127 mm a 508.00 mm)

UNIDADES MOSTRADAS

Pulg. / mm

VELOCIDAD DE ADQUISICIÓN

4 lecturas por segundo

PULSADOR/RECIBIDOR

300-1000 pulsos por segundo

Accesorios

Circulos_Cable_tg930 

Cables para el equipo con distintos largos

Transductores de propósito general

Transductores con línea de retardo intercambiable

SOLICITE MÁS INFORMACIÓN O UNA COTIZACIÓN A UNO DE NUESTROS ASESORES

INFORMACIÓN            COTIZACIÓN

Vistas_Lado2-Tg930
Vistas_Lado1_TG930
Vistas_Arriba_TG930
Vistas_Abajo_Tg930